R.O Unit
Design parameters |
Inlet TDS
Feed temp Max Fe Max H2S Max. SDI Recovery Capacity |
1300-1600 ppm
25˚C 0.05 mg/L Nil <3 75 % 5 m3/hr |
||
Skid | Skid material | steel epoxy coated | ||
Hosing cartridge filter | Model
In/Out Micron rate Material Flow rate Max. operating pressure Max operating Temp |
5×20 ”
1.5 ” 5 microns PVC 10 M3/hr. 86 PSI 45˚C |
||
cartridge filter | Model
Micron Size Purification Material |
M40 PPF (5)
2.5” X 20 ” 5 microns polymer |
||
High pressure pump
|
Manufacturer
Model Origin Power Pressure Flow rate Impeller |
Ebara
EVPMS 10-14/5.5 Italy 5.5 Kw 14 bar 8 m3/hr. stainless steel |
||
Pressure Vessel
|
QTY/vessel membrane
Manufacturer Model Connection Origin Material Max. operating pressure Max. operating Temp |
2
Code line/Pentair 80E30-2 End cap connection India Fiber glass 300 psi 49 ˚C |
||
Membrane | Model Configuration
Dimension Manufacturer Origin Flow rate Salt rejection Max pressure Max. Temp |
BW 400 -8040
8” X 40 ” OLTREMARE ITALY 10500GPD/membrane 99.5% 600 PSI 45 ˚C |
||
Control panel | Control panel
Manufacturer Origin |
PLC
Delta Taiwan |
||
Instrument | Flow meters
Flow rate at rejection line Flow rate at product line TDS Meter Model: TDS 230 ORP Meter : Model: ORP – 3500 High pressure piping Material: Stainless steel 316 Low pressure piping Material: PVC Recycle valve Drain Valve. |
Huge Desalination device
In Stock
Highlights:
- Desalination device
Description
Reviews (0)